MeridianResearch

Lot verification record

MOTS-c Research Material

LotPEP-MOTS-10-L24APEP-MOTS-10

Released

Lot-level analytical record

Certificate of analysis

Test date, issuing laboratory, accreditation/provenance, analytical methods, downloadable signed report, chromatogram, and the full per-test results table.

Batch traceability

Scan to re-open this verification record.

Provenance: Helix Synthesis Partners

Certificate of analysis

Independent third-party
Released
Lot #
PEP-MOTS-10-L24A
Report #
COA-PEP-MOTS-10-001
Sample ID
SMP-PEP-MOTS-10-001
Test date
2026-02-20
Issued date
2026-02-22
Issuing lab
Meridian Analytical Laboratories (SAMPLE)ISO/IEC 17025 · SAMPLE-17025-0001
Methods
HPLC/UPLC, LC-MS, Karl Fischer
Purity
98.1% (Reverse-phase HPLC, UV 214 nm)
MW (expected / observed)
2174.60 / 2174.6 (LC-MS (ESI+))
Reviewed by
A. Researcher (SAMPLE) / R. Reviewer (SAMPLE)
Verification code
VC-PEP-MOTS-10-001(version 1)

Per-test results

TestMethodResultSpecificationOutcome
HPLC / UPLC purityReverse-phase HPLC, UV 214 nm98.1% % area>= 97.0% by HPLCPass
LC-MS identityLC-MS (ESI+)Observed 2174.6; expected 2174.60 g/molMatches expected monoisotopic mass 2174.60Pass
Karl Fischer waterKarl Fischer titration4.8 % w/w<= 8.0%Pass
Fill weight / net contentGravimetric net-content check10 mgLabel claim 10 mgPass

Chromatogram

Chromatogram image for peak inspectionsample/chromatograms/PEP-MOTS-10-001.png
Intended use:
For laboratory research use only.
Prohibited use:
Not for human or veterinary use.
Lot PEP-MOTS-10-L24A — COA verification — Meridian Research Materials